English | 简体中文
Tour
 
About Us
Applications
Products
Education
Case Studies
Event Calendar
Training Schedule
Newsletter
Technical Resources
Careers
Our ISO 9001 Certificate
 

2, 3, and 4 Way Motorized Valves  
Motorized Valve Motorized Valve Radiant

Communications  
Communication: BACnet Communication: Modbus Communication: Internet
HWR Platinum HWRQ Platinum MPC Platinum
MPCQ Platinum Multi-MOD Platinum SRC Platinum

Condensing Boiler Controls  
Mini-MOD-CNC

Digital Set Point Controls  
DIGI-SPAN® HWE-Elite & SEQ-3 Series DIGI-SPAN® MC-Elite Series DIGI-SPAN® SPC-Elite
DIGI-SPAN® TSC-Elite DIGI-SPAN® VSP-Elite ESV - Electronic Steam Valve Control

Domestic Hot Water Controls  
DHW Energy Saver DIGI-SPAN® HWE-Elite & SEQ-3 Series ETV - Electronic Tempering Valves
HWR Platinum HWRQ Platinum Mini-MOD
Mini-MOD-CNC Multi-MOD Platinum Precision Tempering Valves
SQ-Elite Series

Hydronic Heating Controls  
DIGI-SPAN® HWE-Elite & SEQ-3 Series DIGI-SPAN® MC-Elite Series DIGI-SPAN® RSM-Elite
DIGI-SPAN® VSP-Elite HWR Platinum HWRQ Platinum
Mini-MOD Mini-MOD-CNC Multi-MOD Platinum
SQ-Elite Series ZCP
Q: My outdoor sensor reading does not match the actual temperature.
A:The outdoor sensor measurement may vary based on its location and its sun exposure. In most cases it will never match a weather station that is located several miles away. most current Heat-Timer controls have a Trim feature which allows the sensor reading to be slightly modified just a few degrees to satisfy similar circumstances. If the difference was large, then check the sensor by disconnecting one of its wires from the control. The control should read OPEN. If not, contact technical support.
Related Product: MPC Platinum | ETV - Electronic Tempering Valves | DIGI-SPAN® HWE-Elite & SEQ-3 Series | HWR Platinum | HWRQ Platinum | DIGI-SPAN® MC-Elite Series | Sensors: Mini-MIG | Mini-MOD | MPCQ Platinum | Multi-MOD Platinum | DIGI-SPAN® RSM-Elite | SQ-Elite Series | DIGI-SPAN® SPC-Elite | SRC Platinum | DIGI-SPAN® TSC-Elite | TMC and Solenoid Valves | DIGI-SPAN® VSP-Elite | Sensors | Mini-MOD-CNC
Related Application:
Q: Why is my temperature sensor reading Open on the control display?
A:Remove the sensor wires from the control and check for continuity across the wires with and meter. If no continuity existed, check or replace the wires. if continuity did exist, then contact technical support.
Related Product: MPC Platinum | ETV - Electronic Tempering Valves | DIGI-SPAN® HWE-Elite & SEQ-3 Series | HWR Platinum | HWRQ Platinum | DIGI-SPAN® MC-Elite Series | Sensors: Mini-MIG | Mini-MOD | MPCQ Platinum | Multi-MOD Platinum | DIGI-SPAN® RSM-Elite | SQ-Elite Series | DIGI-SPAN® SPC-Elite | SRC Platinum | DIGI-SPAN® TSC-Elite | TMC and Solenoid Valves | DIGI-SPAN® VSP-Elite | Sensors | Mini-MOD-CNC
Related Application:
Q: Why is my temperature sensor reading Short on the control display?
A:Remove one of the sensor wires from the control. The control display should change and display OPEN. Then check the sensor wiring specifically around spliced areas. If wiring was good, then disconnect the sensor wires from the control and check the sensor wires with an Ohm meter. The readings should match the sensor temperature chart on the control manual. It not, then replace the sensor. If after removing one of the sensor wires the control read SHORT, then contact tech support.
Related Product: MPC Platinum | ETV - Electronic Tempering Valves | DIGI-SPAN® HWE-Elite & SEQ-3 Series | HWR Platinum | HWRQ Platinum | DIGI-SPAN® MC-Elite Series | Sensors: Mini-MIG | Mini-MOD | MPCQ Platinum | Multi-MOD Platinum | DIGI-SPAN® RSM-Elite | SQ-Elite Series | DIGI-SPAN® SPC-Elite | SRC Platinum | DIGI-SPAN® TSC-Elite | TMC and Solenoid Valves | DIGI-SPAN® VSP-Elite | Mini-MOD-CNC
Related Application: Sensors
Q: Why does my Heat-Timer hot water reset control (HWR) flash OPN instead of the outdoor temperature?
A:Heat-Timer controls use the code OPN when they can not detect a sensor. For example, if someone were working in the building and cut the wires leading to the outdoor sensor, the HWR would begin to flash OPN to signal that the sensor was no longer attached. To find the source of the OPN reading, first make sure that the outdoor sensor wires are attached to the input terminals (the IT terminals in the case of an HWR). Then place a jumper wire across the input terminals (IT). The display should change to read SH-I (the code for a shorted sensor). If the display does change, the HWR is working properly. Check the wires to make sure they are not broken, and locate the sensor to see if it has been damaged
Related Product: MPC Platinum | HWR Platinum | HWRQ Platinum | Mini-MOD | MPCQ Platinum | Multi-MOD Platinum | SQ-Elite Series | Mini-MOD-CNC
Related Application: Steam Heating Controls | Modulating Controls | Sequencing Controls | Digital Set Point Controls | Tempering Valves
Q: Why doesn't my Heat-Timer Remote Communication system show the history of the space temperatures? I can communicate with the system and set any of the panel parameters, but when I go to check how well the system is holding space temperatures, I get only blanks.
A:To keep a record of the space temperatures (as well as the outdoor temperature and system sensor), the Remote Intercept must know what the time and date are. Use the SPT (Set Present Time) command. This will prompt for the present date and for the time of day. Once the system has this information, it will keep a log of the histories.
Related Product: MPC Platinum | HWR Platinum | HWRQ Platinum | MPCQ Platinum | Multi-MOD Platinum | SRC Platinum
Related Application: Steam Heating Controls | Hydronic Heating Controls | Modulating Controls | Communications

Modulating Controls  
DIGI-SPAN® MC-Elite Series DIGI-SPAN® RSM-Elite DIGI-SPAN® VSP-Elite
ESV - Electronic Steam Valve Control ETV - Electronic Tempering Valves Mini-MOD
Mini-MOD-CNC Multi-MOD Platinum

Motorized Valves and Controls  
DIGI-SPAN® HWE-Elite & SEQ-3 Series DIGI-SPAN® MC-Elite Series ESV - Electronic Steam Valve Control
ETV - Electronic Tempering Valves HWR Platinum Motorized Valve
Motorized Valve Radiant MPC Platinum SQ-Elite Series
SRC Platinum

OBSOLETE Products  
Gold Series Controls
(Obsolete)
HWE Series (Old Style)
(Obsolete)
HWM Heatrol Series
(Obsolete)
MCA, MCP, MCF
(Obsolete)
SEQ-6, 12, 24, 6P, 12P
(Obsolete)
TGC
(Obsolete)
Visual Gold Plus 5.17
(Obsolete)

Pump Controls  
PLL (Pump Lead-Lag Control) SCP-6 (System Control Panel)

Radiant Controls and Valves  
DIGI-SPAN® HWE-Elite & SEQ-3 Series DIGI-SPAN® MC-Elite Series DIGI-SPAN® RSM-Elite
DIGI-SPAN® SPC-Elite DIGI-SPAN® TSC-Elite DIGI-SPAN® VSP-Elite
HWR Platinum HWRQ Platinum Mini-MOD
Mini-MOD-CNC Motorized Valve Radiant SMC-Gold
SQ-Elite Series ZCP

Sensors  
MLS/MLS-A OTM (Oil Tank Monitor) Sensors
Sensors: Mini-MIG Sensors: Wireless Network Sensor System

Sequencing Controls  
DIGI-SPAN® HWE-Elite & SEQ-3 Series DIGI-SPAN® TSC-Elite HWRQ Platinum
Mini-MOD-CNC MPCQ Platinum SQ-Elite Series

Snow Melt Controls  
DIGI-SPAN® RSM-Elite SMC-Gold

Steam Heating Controls  
DIGI-SPAN® MC-Elite Series DIGI-SPAN® SPC-Elite DIGI-SPAN® TSC-Elite
EPU EPU-CH ESV - Electronic Steam Valve Control MPC Platinum
MPCQ Platinum Multi-MOD Platinum SQ-Elite Series
SRC Platinum

Steam Outdoor Reset  
EPU EPU-CH MPC Platinum MPCQ Platinum

Tempering Valves  
ESV - Electronic Steam Valve Control ETV - Electronic Tempering Valves Precision Tempering Valves
TMC and Solenoid Valves

VARIVALVE® Radiator Air Vents  
VARIVALVE®